> it seems that the Link Sequential Spin Systems forgets about the
> segments after a project reload. Those are still available in the Spin
> Systems dialogue, so it seems they are saved ok (see picture).
Was just a missing graphical update. Now fixed.
> Oh and by the way: Is there a way to set a sequential link between to
> arbitrary spin systems? Sometimes neighbours don't show up in the Link
> Sequential Spin Systems window.
On a resonance assigned inter-residue peak - Mouse Menu::Assign::Set
Sequential Spin Systems - and then the appropriate option according to the
peak dims.
Also the Seq Segment column is settable in the spin system table.
T.
-------------------------------------------------------------------------------
Dr Tim Stevens Email: [log in to unmask]
Department of Biochemistry [log in to unmask]
University of Cambridge Phone: +44 1223 766018 (office)
80 Tennis Court Road +44 7816 338275 (mobile)
Old Addenbrooke's Site +44 1223 364613 (home)
Cambridge CB2 1GA WWWeb: http://www.bio.cam.ac.uk/~tjs23
United Kingdom http://www.pantonia.co.uk
-------------------------------------------------------------------------------
------ +NH3CH(CH(CH3)OH)C(O)NHCH(CH(CH3)CH2CH3)C(O)NHCH(CH2CH2SCH3)CO2- -------
-------------------------------------------------------------------------------
|