> If I am in the pop-up Shift Differences and right click on the shift
> differences table and choose graph then I cannot choose residue number as
> the x-axis.
It occurs to me that it may be due to chain letters which is why the issue
is not always visible. Maybe try turning the chain letters off (Peak Draw
Parameters).
I suspect that to make the system work well with all of these combinations
of letters and numbers we'd need system for category axes. But that is a
major modification of the graphing apparatus. Putting it on the to-do list
is the best I can muster at present.
T.
-------------------------------------------------------------------------------
Dr Tim Stevens Email: [log in to unmask]
Department of Biochemistry [log in to unmask]
University of Cambridge Phone: +44 1223 766018 (office)
80 Tennis Court Road +44 7816 338275 (mobile)
Old Addenbrooke's Site +44 1223 364613 (home)
Cambridge CB2 1GA WWWeb: http://www.bio.cam.ac.uk/~tjs23
United Kingdom http://www.pantonia.co.uk
-------------------------------------------------------------------------------
------ +NH3CH(CH(CH3)OH)C(O)NHCH(CH(CH3)CH2CH3)C(O)NHCH(CH2CH2SCH3)CO2- -------
-------------------------------------------------------------------------------
|