Threshold the FA image at 1, and see where they are - I bet 99% will
be outside the brain...
T
On 12 Dec 2007, at 10:12, S. Groppa wrote:
> Dear List,
>
>
>
> still trying to improve the data quality from our scanner.
>
> here 2 histograms with a great ask to comment on the quality of
> these...
>
>
>
>
>
> 1. one repeat of: 4 subsequent scans of 1 b=0 + 8 different
> directions (all: 4 b=0, 32 directions) + fslmerge
>
>
>
> 2. two repeats of: 32 directions + 1 b=0 > fslmerge
>
>
>
> There are still values over 1, how comes?
>
>
>
> thanks a lot
>
>
>
> sincerely
>
>
>
> S. Groppa
>
>
>
> <Hist1.jpg>
> <Hist2.jpg>
|