Hello,
if the first regressor is the regressor you would like to test for a
positive correlation,
indeed a simple "1" should be it. Make sure that you have activated the
"T-contrast" option and not the "F-contrast" option.
If it remains unclear you could send a jpg/screenshot of your design
matrix round.
br,
Philipp
|