On Tue, 24 Oct 2006, Tim Jenness wrote:
> I think this boils down to "user beware" and "not our problem gov" and "make
> sure that your local software that needs the endianness set either does the
> conversion itself or does a PSX_PUTENV or actually just wraps its calls in a
> shell script that will set the correct value OR always uses the same unit
> number for read and sets G95_UNIT_ENDIAN_x"
>
OR
- build the starlink software with the G95_ENDIAN variable set to your
choice so that all files writen during the build will be correct for you
OR
- remove the ifc files and replace them with the ifl files (as I suggested
earlier). There may be other files that are installed that need tweaking
but ifc files will be the biggest culprit.
--
Tim Jenness
JAC software
http://www.jach.hawaii.edu/~timj
|