Sorry, I wasn't thinking straight - I was thinking about Featquery
not Featwatcher. Hence this does sound odd, as long as the lower-
level FEATs ran ok.
Please could you upload the data and we'll have a quick check.
Cheers.
On 22 Oct 2006, at 08:26, Steve Smith wrote:
> Hi,
>
> Featwatcher is attempting to find peak-peak EV/contrast heights
> from the FEAT outputs and failing.
>
> Did you run the lower and higher levels with the latest version of
> FEAT (i.e. from FSL 3.3)? Did the FEATs, including the higher-
> level, appear to run successfully?
>
> If the answer to both is yes then most likely the files in
> the .feat directories have become corrupted. If they haven't this
> is possibly a bug, in which case please could you upload the data
> for us to look at:
>
> Please upload the files in a single compressed tarfile to
> http://www.fmrib.ox.ac.uk/cgi-bin/upload.cgi
> and then email me the upload ID.
>
> Cheers, Steve.
>
>
> On 20 Oct 2006, at 22:44, Joongnam Yang wrote:
>
>> Dear all,
>>
>> I was doing a single-group average using "model setup wizard" (a
>> simple
>> average of two subjects, using *.feat directories) and
>> got the following error message in the middle of running of Feat
>> Watcher, on
>> the command line.
>>
>> syntax error in expression "0 + ": premature end of expression
>> while executing
>> "expr $mean_lcon + $mean_lcon_incr "
>> (procedure "feat5:proc" line 291)
>> invoked from within
>> "feat5:proc [ file rootname [ lindex $argv 0 ] ]"
>> (file "/usr/local/fsl/bin/feat" line 16)
>>
>> and the FEAT stopped.
>>
>> Would someone suggest a hint on how to go about this?
>>
>> Nam.
>
>
> ----------------------------------------------------------------------
> -----
> Stephen M. Smith, Professor of Biomedical Engineering
> Associate Director, Oxford University FMRIB Centre
>
> FMRIB, JR Hospital, Headington, Oxford OX3 9DU, UK
> +44 (0) 1865 222726 (fax 222717)
> [log in to unmask] http://www.fmrib.ox.ac.uk/~steve
> ----------------------------------------------------------------------
> -----
>
>
>
------------------------------------------------------------------------
---
Stephen M. Smith, Professor of Biomedical Engineering
Associate Director, Oxford University FMRIB Centre
FMRIB, JR Hospital, Headington, Oxford OX3 9DU, UK
+44 (0) 1865 222726 (fax 222717)