> I have segmented MRT images with SPM5.
> I need GM and WM segments with 1*1*1 mm resolution.
> But only the native ones are in this resolution (1*1*1 mm).
> The normalised and normalised modulated GM and WM segments
> are in 2*2*2 mm resolution.
> How and where can I change the parameters from 2*2*2 mm to
> 1*1*1 mm so that the normalised and normalised modulated GM
> and WM segments are also in 1*1*1 mm resolution?
First of all, why do you need spatially normalised tissue classes at 1mm
resolution? If you really need them at this voxel size, then you can use the
Normalise button, selecting the write normalised only option. Specify the
*_seg_sn.mat file (not the _seg_inv_sn.mat) for the normalisation parameters,
and the corresponding c1, c2 and c3 as the images to write normalised. Then
you can specify any voxel size you like for the spatially normalised images.
Best regards,
-John
|