Thank you, sir.
Tom
Thomas M. Malone
Research Assistant
Hoglund Brain Imaging Center
MailStop 1052
3901 Rainbow Boulevard
University of Kansas Medical Center
Kansas City, KS 66160
Phone: 913 588 9070
http://www.kumc.edu/hoglund/
>>> John Ashburner <[log in to unmask]> 05/18/05 2:46 PM >>>
> I'm a very new user of SPM2 and was wondering if I should use EMS
for
> segmentation or if equivalent algorithms are already included in
SPM2.
Related algorithms are included in SPM2, but segmentation in SPM2 does
not
include a number of the features that are found in EMS. These
include:
* The use of MRFs to improve segmentation accuracy.
* Automatically segmenting lesions from multi-spectral data.
Segmentation in SPM5b will do some things that EMS does not, but it
still
won't cope with lesions or use MRFs.
Best regards,
-John
|