Now sL = 19 and size(c) = 19, but size(c,1) is still equal to 1.
Which I think is the problem, since the line of code is:
elseif size(c,1) ~= sL,
error(['not contrast dim. in ' mfilename ' ' set_action]);
-Melissa
Quoting [log in to unmask]:
> Even after correcting that mistake it is giving me the same error.
> Any help would be appreciated.
>
> -Melissa
>
> Quoting [log in to unmask]:
>
> > Thanks, I'm running it again, I had missed changing one parameter in one
> of
> > my
> > subject specific m-files which I hadn't thought of looking at, since it
> had
> > gone
> > all the way through that step. So it was looking for 8 conditions instead
> of
> > 9.
> >
> > -Melissa
> >
> > Quoting "K. Prasad" <[log in to unmask]>:
> >
> > > Hello,
> > >
> > > The length of the contrast needs to be of the same
> > > size as the number of columns in design matrix
> > > (including the constant terms).
> > >
> > > Hope this helps
> > > -krishna
> > >
> > > --- Melissa Work <[log in to unmask]> wrote:
> > >
> > > > Dear SPMers,
> > > > I've been using SPM99 for awhile now, with few
> > > > problems. However, while running
> > > > spm_bch yesterday, I came across an error I've never
> > > > seen before, despite using
> > > > this method for over a year now, and not editing any
> > > > of the spm_*.m files.
> > > >
> > > > ">> spm_bch('analyses','FMRI')
> > > > ??? Error using ==> spm_FcUtil
> > > > not contrast dim. in spm_FcUtil c
> > > >
> > > > Error in ==> /pkg/spm99/spm_bch_GetCont.m
> > > > On line 68 ==> contrast =
> > > > spm_FcUtil('Set',names{n}, types{n}, 'c',
> > > > values{n}, sX);
> > > >
> > > > Error in ==> /pkg/spm99/spm_bch.m
> > > > On line 161 ==> s = spm_bch_GetCont;
> > > > "
> > > >
> > > > Has anyone had this problem? I did some basic
> > > > debugging, and all I discovered
> > > > was that the error originates in some code which
> > > > compares size(c,1) to sL, and
> > > > that sL = 17, while size(c,1) = 1, and size(c) = 19.
> > > >
> > > > Any thoughts?
> > > >
> > > > -Melissa Work
> > > > University of Pennsylvania
> > > >
> > > > -------------------------------------------------
> > > > This mail sent through IMP: http://horde.org/imp/
> > > >
> > >
> > >
> > > =====
> > > Krishna P. Miyapuram
> > > Work : Graduate Student, Dept of Anatomy, Univ of Cambridge
> > > Home : 25, Parkside, Room 10 (Phone +44 - 1223 - 476858
> > > Address : Downing College, Regent Street, Cambridge, CB21DQ, England
> > > URL : http://people.pwf.cam.ac.uk/kpm23/index.html
> > >
> > >
> > >
> > > __________________________________
> > > Do you Yahoo!?
> > > Jazz up your holiday email with celebrity designs. Learn more.
> > > http://celebrity.mail.yahoo.com
> > >
> >
> >
> >
> >
> > -------------------------------------------------
> > This mail sent through IMP: http://horde.org/imp/
> >
>
>
>
>
> -------------------------------------------------
> This mail sent through IMP: http://horde.org/imp/
>
-------------------------------------------------
This mail sent through IMP: http://horde.org/imp/
|