Hi Zoltan,
do you really need the DICOM format? Philips does have an export
routine which writes any scanner data as par and rec data. This
format can be easily converted into analyze. I could send you the
matlab code if needed.
If you want to or if you have to stick to DICOM, MRIcro
(http://people.cas.sc.edu/rorden/mricro.html) from Chris Rorden
should do the job for you
Best wishes and good luck!
Lukas
Datum: Wed, 2 Feb 2005 16:46:43 +0000
Antwort an: Zoltan Nagy <[log in to unmask]>
Von: Zoltan Nagy <[log in to unmask]>
Betreff: [SPM] DTI data from Philips
An: [log in to unmask]
> Hi SPM list,
> I have some DTI data from a Philips Intera which I need to convert from
> DICOM to Analyze using SPM2. If anybody has any experience and would share
> some hints or bits of code it would be appreciated.
>
> Thanks in advance,
> Zoltan
>
> **********************************
> Zoltan Nagy
> Karolinska Institute
> Neonatology
> Astrid Lindgren's Children's Hospital Q2:07
> 171 76 Stockholm, Sweden
>
> Phone: +46-8-517-76118
> Fax: +46-8-517-77353
> E-mail: [log in to unmask]
> **********************************
Lukas Scheef, MD, MSc
MR-Tomography
Department of Radiology
University of Bonn
Sigmund-Freud-Straße 25
D-53105 Bonn
Fax: +49-228-287-5598
Phone:+49-228-287-4496
E-mail: [log in to unmask]
|