Hi All,
I added a couple of check to Gstat.
Best Regards,
Min
The GIISQuery_SiteInfo filter now checks:
1) if the sitename matches what is found in the GOCDB
2) if the version is recent ("LCG_2_3_0" or"LCG_2_2_0")
If these check fail, a NOTE alert level is raised
There is a new Filter added for sites running BDII nodes:
BDIINode Performance Filter: Checks BDII node performance
Column Name: bnode
Conditions Alert level
-------------------------------------
No problems OK
Response time > 5 secs INFO
No entries found NOTE
This filter queries BDII nodes found in the GOCDB. The number
of entries found and the response time(ms) are recorded.
To query the bdii the following command and options are used:
ldapsearch -xL -s one -l 10 -h -p 2170
-b 'mds-vo-name=local,o=grid'
This query only searches one level below the basesearch
Provided. The number of entries represents the number of sites
Found in the bdii query.
The current results and graphs for each sites BDII's can be
found in the site's detailed reports. The following suffixes
are used after the BDII hostnames:
BE BDII Entries
BT BDII Response Times
|