Hi,
Sorry for not answering before, but I was away for few days. There
were two reasons why I started to use the non-standard port 9443:
- SFT server normally runs on a MONBOX machine, where port 8443 is
occupied by R-GMA (secure connector of tomcat) and I don't want to
run SFT report page under tomcat
- ports below 1024 are not allowed at CERN for incoming access for
grid machines, and I didn't want to ask for special access
I didn't realise that this will cause problems - but obviously I was
wrong. I will try to figure out which port from the standard EGEE/LCG
list I can use on SFT server and I will then configure it as
additional port where SFT reports can be accessed. But this will take
some time (by monday?)
Piotr
On Sep 28, 2005, at 11:50 AM, Eduardo Huedo Cuesta wrote:
> Hi,
>
> Did someone answer the below question regarding port 9443?
> At INTA-CAB we are not able to read SFT reports. Luckily, we
> receive e-mail alarms from our partners at CESGA but we can't check
> the details of failures.
>
> Regards,
>
> Eduardo.
>
> Stephen Childs wrote:
>
>
>> Can I ask why the detailed results of the SFTs are hosted on port
>> 9443? Is there any reason they can't be served on a standard https
>> port (443 or 8443)? All our external web access goes through a web
>> proxy which (unsurprisingly) doesn't allow port 9443. I don't
>> particularly want to ask for special access on this port as I
>> don't see the need. We have other more worthwhile battles to fight
>> on this front and I don't want to use up my credit with the
>> firewall admins!
>>
>> As I've said before, it's hard enough convincing site admins that
>> we really need all of the Grid ports open; we shouldn't also need
>> to ask them to open up non-standard ports for straightforward web
>> accesses.
>>
>> Stephen
>>
>>
>>
>
> --
> **************************************************
>
> Eduardo Huedo Cuesta, PhD
> Laboratorio de Computación Avanzada, Simulación
> y Aplicaciones Telemáticas
> Centro de Astrobiología (CSIC-INTA)
> Ctra. de Ajalvir Km 4
> 28850 Torrejón de Ardoz, Madrid
> Spain
>
> Tel: +34 91 520 64 28
> Fax: +34 91 520 10 74
> Email: [log in to unmask]
> Web: http://www.cab.inta.es/~huedoce
>
> **************************************************
>
> GridWay, The Way to Grid! http://www.gridway.org
>
|