Dear colleagues,
Regarding to Bart proposal for measuring first ray "stiffness", there is a
system from Fuji called Fuji Prescale Film whose utility is the same. For
further information you can check the website
http://www.oandp.org/jpo/library/1990_02_130.asp where an old study
describes it. The device is still available on the market.
Regards,
Javier
Private Practice
Barcelona-Spain-
-----Mensaje original-----
De: A group for the academic discussion of current issues in podiatry
[mailto:[log in to unmask]]En nombre de Bart Van Gheluwe
Enviado el: miercoles, 14 de abril de 2004 14:00
Para: [log in to unmask]
Asunto: Re: Some further reflections on Metatarsal Ray Dorsiflexion
Stiffness
Dear all,
Jay ended his message with the words::
>I think you have me sold on the "stiffness" term. Now
>I think we should evaluate the unit or method by which
>we can communicate this variable.
And that is exactly my point. How will we do that in a way that can be
implemented during a normal podiatric session ?
I tried to come up with something simple. How do you like the following
device.
Everybody normally has some sofft PPT like material of different densities
around. Cutting a small piece of a square centimeter and glueing a stiff
thin plate at the top and the bottom end of it, produces a crude pressure
measurement device.
Next step is to calibrate this "load cell" by loading it with known weights
till top and bottom plate are at their closest position, with the soft
material maximally flatten. Sophisticating the devise attaching a small
scale at the side of the device enables intermediate readings.
Using different material densities produces load cells with different
sensitivities.
Now, in order to measure stiffness of the first ray, we proceed as usual as
for measuring 1st ray mobility according to Root, but with the load cell
under the 1st meta head. Monitoring the deflection of the 1st meta with
the load cell maximally ( or partially when using the attache scale
division) flatten, enables a crude estimation of the joint stiffness.
I did not try this device, it is just a first mental exercise. Who is
willing to try it out or come up with a different solution? The
competition for the best hobyist among us is open.
Have fun,
Bart
*******************************************************************
Bart Van Gheluwe
Laboratory of Biomechanics
Vrije Universiteit Brussel -Fac. LK
Vakgroep BIOM
Pleinlaan 2, 1050 Brussel, Belgium
Tel.: 02/629.27.33 (31)
Fax: 02/629.27.36
*******************************************************************
-----------------------------------------------------------------
This message was distributed by the Podiatry JISCmail list server
All opinions and assertions contained in this message are those of
the original author. The listowner(s) and the JISCmail service take
no responsibility for the content.
to leave the Podiatry email list send a message containing the text
leave podiatry
to [log in to unmask]
Please visit http://www.jiscmail.ac.uk for any further information
-----------------------------------------------------------------
-----------------------------------------------------------------
This message was distributed by the Podiatry JISCmail list server
All opinions and assertions contained in this message are those of
the original author. The listowner(s) and the JISCmail service take
no responsibility for the content.
to leave the Podiatry email list send a message containing the text
leave podiatry
to [log in to unmask]
Please visit http://www.jiscmail.ac.uk for any further information
-----------------------------------------------------------------
|