The lock file is /var/lock/subsys/edg-gatekeeper.
Unfortunately due to a bug, even removing it does
not help! You have to kill all job-manager processes
before restarting the gatekeeper.
Jose Gabadinho
On Friday 14 November 2003 13:35, you wrote:
> Hi,
>
> I had similar problem on CE, when I wanted to
> restart gatekeeper. It says: address already in use,
> lockfile exist. I couldn't find lockfile and
> restart was not working , so I rebooted the machine ;-)
> Now it works, but I don't know the origin of the
> problem.
> cheers,
> Gergo
>
> On Fri, 14 Nov 2003, Peer Hasselmeyer wrote:
> > Hi,
> >
> > since upgrading to 1_1_1 (I think) I can't restart the gatekeeper
> > anymore. Shutting it down works, but, after that, starting it
> > again is not possible. Only rebooting the machine helps.
> > /var/log/messages says that the address is already in use (see
> > below). Unfortunately, it doesn't say which port it wants to bind
> > to. According to netstat, port 2119 is not in use. Did anybody
> > encounter a similar problem? Does anybody know if the
> > edg-gatekeepter wants to bind to nother ports as well?
> >
> >
> > Thanks for any response,
> >
> > Peer
> >
> >
> > --- /var/log/messages ---
> > Nov 14 12:09:57 hik-lcg-ce GRAM gatekeeper[31413]:
> > /opt/edg/sbin/edg-gatekeeper pid=31413 starting at Fri Nov 14 12:09:57
> > 2003 Nov 14 12:09:57 hik-lcg-ce GRAM gatekeeper[31413]: error check
> > net_setup_anon_listener bind: Address already in use Nov 14 12:09:57
> > hik-lcg-ce globus-gatekeeper: edg-gatekeeper startup failed
> >
> > --
> > Dr. Peer Hasselmeyer [log in to unmask]
> > Forschungszentrum Karlsruhe Tel.: +49-7247-828601
> > Institute for Scientific Computing / Inst. f. Wissenschaftliches Rechnen
> > Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
|