Dear Smith and FSL expert,
Many thanks for your help. The FEAT can work now smoothly. May I ask
another two questions?
1. How to change the template brain in the report and registrate the
result image on it? I have a standard MR with size 91*109*91 and the
subject image size is 79*95*68. Is there any problem to use the template
MR to registrate the FEAT result ?
2. I have the cognitive sorce to every controls and disease subjects. How
to use the score to find the regresion area by the FEAT ?
Thank for the help.
JLH
|