Dear Pisti,
> We experience problems importing a ROI mask image file (search volume
> in <S.V.C.> (small volume corrections)) just for one particular fMRI
> data set but not for any other data set we used in the past. The
> following error message appears:
>
>
> Mask image rotated/sheared!
> (relative to SPM image)
> Can't use for SVC.
Does this FMRI dataset have a non trivial mat file (VOL.M), by which I mean one
which specifies some rotations? These cause nonzero off-diagonal elements in
the first three columns of the M matrix. This might occur if you had (for
example) coregistered the dataset to another session. In such a case the
dataset may not be in perfect voxel alignment with the mask, which is what
causes this error.
Best,