Hi Chris,
Thanks for the info, though the problem we're having is
more fundamental. What we need is a piece of software
that will enable us to read the contents of the disk, since
we are enable to mount the MO disk using standard SUN commands.
Once we've cracked that chestnut - the software you suggest
will be really handy. Thanks.
Yours,
Jon.
_____________________________________________________
Jonathan Brooks Ph.D. (Research Fellow)
Magnetic Resonance and Image Analysis Research Centre
University of Liverpool, Pembroke Place, L69 3BX, UK
tel: +44 151 794 5629 fax: +44 151 794 5635
On Tue, 11 Apr 2000, Chris Rorden wrote:
>Jon-
>
>If you have MS Windows, you can convert the images to Analyze format using
>my MRIcro freeware:
> http://www.mrc-cbu.cam.ac.uk/~chris.rorden/mricro.htm MRIcro can read
>Analyze, DICOM, ECAT 6/7, Genesis, Interfile and NEMA format images, and
>convert them to Analyze.
>
>Other freeware converters worth looking at are Medcon:
> http://petaxp.rug.ac.be/~nolf/welcome.html#CONVERSION
>and DICOM2
> http://www.hds.utc.fr/~barre/medical/dicom2/
>both of which run on a variety of platforms.
>
>-chris
>
>______________________________________________________________
> Chris Rorden
> Cognition and Brain Sciences Unit Department of Psychology
> Medical Research Council University of South Carolina
> 15 Chaucer Rd Columbia, SC 29208
> Cambridge CB2 2EF tel 803-777-1582
> http://www.mrc-cbu.cam.ac.uk/~chris.rorden/
>
>On Tue, 11 Apr 2000, Mr J.C.W. Brooks wrote:
>
>> Hello,
>>
>> I have been sent an optical disk, which was created using
>> an Advantage Windows workstation (part of a GE MRI suite).
>> The disk isn't formatted using a standard SUN format, and as
>> such is a DICOM storage medium (whatever that is!). Does anyone
>> know of any freely availble software for reading these data?
>>
>> Details:
>> The disk is a MaxOptix 2.3Gb magneto-optical disk
>> It holds DICOM 3.0 image data.
>>
>> Any help would be greatly appreciated.
>>
>> Yours,
>>
>> Jon.
>>
>> _____________________________________________________
>> Jonathan Brooks Ph.D. (Research Fellow)
>> Magnetic Resonance and Image Analysis Research Centre
>> University of Liverpool, Pembroke Place, L69 3BX, UK
>> tel: +44 151 794 5629 fax: +44 151 794 5635
>>
>>
>>
>
>
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|