Dear David,
Is it possible to send some more information about the specs of the
input/output images, like dimensions in voxels, voxel sizes in mm,
origin co-ordinates etc? This description is a little in the "black box"
style...
> The target is in my case a T1 MRI (SPGR), as I need the PET images (water)
> to be in the same space as the MRI. The PET images lack the dorsal part of
> the brain due to field of view limitations. I specified the average water
> PET image as the object, and then tell it to apply the determined
> registration parameters to individual water images.
> The problem seems to be that the r*.img's (individual or mean) are not even
> budged from their original orientation, let alone correctly registered on
Which options did you pass to the registration routine?
> the MRI. Am I doing something wrong? Is SPM? I did find something in the
> mailbase about the origin of the images, and none of the origins are 0, if
> that's relevant.
They shouldn't. They should be somewhere in the middle...
> Another curious thing is that the supposedly co-registered MRI's are twice
> their original size-- that also seems funny.
Indeed. Once again, could you please provide (me/us) with some
additional info?
Best regards,
Alle Meije
--